Comparison of the Radiation Absorption Properties of PbO doped ZrB2 Glasses by using GATE-GEANT4 Monte Carlo Code and XCOM Programme

[ X ]

Tarih

2023

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Prof.Dr. İskender AKKURT

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The aim of this study is to investigate the gamma-ray radiation absorption properties of ZrB2 (zirconium diboride), which is used in the nuclear industry, space industry, military industry, and especially in the ceramic industry, and determines the effect of PbO additive in the shielding. Also, the Geant4 Application Tomographic Emission (GATE-GEANT4) Monte Carlo computer code tested for its usability in place of the XCOM computer program with an appropriate geometry. Within this scope, the shielding properties of ZrB2, Pb0 and 50%ZrB2.50%Pb0 glasses at 511, 662, 1173, 1274 and 1332 keV gamma energies were calculated by the GATE-GEANT4 Monte Carlo code and compared with the XCOM computer program. The linear attenuation coefficient and half-value layer were calculated by using the mass attenuation coefficient values obtained with the codes. In line with these results, it is possible to say that 50%PbO additive increases the shielding quality of ZrB2 glasses. On the other hand, the simulated GATE-GEANT4 Monte Carlo code values were found to be compatible with XCOM.. © 2023, Prof.Dr. İskender AKKURT. All rights reserved.

Açıklama

Anahtar Kelimeler

GATE/GEANT4, Radiation shielding, XCOM, ZrB<sub>2</sub>

Kaynak

International Journal of Computational and Experimental Science and Engineering

WoS Q Değeri

Scopus Q Değeri

Q4

Cilt

9

Sayı

3

Künye