Usage of R513A as an alternative to R134a in a refrigeration system: An experimental investigation based on the Kigali amendment

dc.contributor.authorDağıdır, Kayhan
dc.contributor.authorBilen, Kemal
dc.date.accessioned2025-03-17T12:22:46Z
dc.date.available2025-03-17T12:22:46Z
dc.date.issued2024
dc.departmentTarsus Üniversitesi
dc.description.abstractIn this study, the use of the alternative refrigerant R513A instead of R134a in a mechanical vapor compression refrigeration system was experimentally investigated in terms of the first and second laws of thermodynamics on the basis of the Kigali Amendment. The investigations were carried out approximately at a cooling medium temperature (TL) of 0, 4, and 8 °C and a heating medium temperature (TH) of 30, 35, and 40 °C without any modifications to the system. The energetic and exergetic performance parameters obtained in this study were related to the amount of refrigerant in accordance with the criteria restricting the use of fluorinated greenhouse gases after the Kigali Amendment. Accordingly, the required refrigerant mass flow rate per unit energetic (power input, cooling capacity, COP value) and exergetic (total exergy destruction rate and exergy efficiency) performance parameters were determined. As a result, the system was found to operate safely when R513A was used instead of R134a without any modification. In addition, the refrigerant mass flow rate per unit power input was almost the same for both refrigerants. However, R513A was found to have approximately 15 % more refrigerant mass flow per unit cooling capacity than R134a. This resulted in the refrigerant mass flow rate per unit COP being approximately 20 % higher for R513A. On the other hand, the refrigerant mass flow rate per unit exergy efficiency calculated for R513A was found to be about 15 % higher than R134a. © 2024 The Author(s)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK, (119M074)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK
dc.identifier.doi10.1016/j.ijft.2024.100582
dc.identifier.issn2666-2027
dc.identifier.scopus2-s2.0-85184480284
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.ijft.2024.100582
dc.identifier.urihttps://hdl.handle.net/20.500.13099/1364
dc.identifier.volume21
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofInternational Journal of Thermofluids
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20250316
dc.subjectAlternative refrigerant
dc.subjectEnergetic analysis
dc.subjectExergetic analysis
dc.subjectKigali amendment
dc.subjectR134a
dc.subjectR513A
dc.subjectVCRS
dc.titleUsage of R513A as an alternative to R134a in a refrigeration system: An experimental investigation based on the Kigali amendment
dc.typeArticle