Optimization of heat and fluid flow over curved trapezoidal winglet pair type vortex generators with one-row and three-row

dc.authoridKuru, Muhammet Nasif/0000-0002-5941-1221
dc.contributor.authorKuru, Muhammet Nasif
dc.date.accessioned2025-03-17T12:27:39Z
dc.date.available2025-03-17T12:27:39Z
dc.date.issued2023
dc.departmentTarsus Üniversitesi
dc.description.abstractPassive heat transfer enhancement methods are frequently chosen to achieve higher thermo-hydraulic performances in engi-neering applications because they do not require external energy. One of the most popular passive methods for increasing heat transfer and improving the cooling effects of heat transfer surfaces is the use of vortex generators (VGs). However, the pressure drop generated by the usage of VGs must be controlled. This work is interested in the number (one, three) and geo-metric dimensions of VGs in the rectangular channel. Numerical optimization studies are carried out for heat and fluid flow over curved trapezoidal winglet pair (CTWP) type VGs for one-row and three-row to obtain optimum geometric dimensions of one-row and three-row of CTWP types VGs in the rectangular channel under incompressible and turbulent flow and con-jugate heat transfer assumptions. Heat transfer and pressure drop values are compared in terms of j/j(0) (the ratio of Colburn factor with CTWP to without it) and f/f0 (the ratio of friction factor with CTWP to without it), respectively. The optimiza-tion problems are solved with no constraints in the workflows. Multi-Objective Genetic Algorithm (MOGA) is used for the computations where the maximization of j/j0 and minimization of f /f0 are the two objective functions. Thermo-hydraulic performances ( R = (j/j(0))/(f/f(0))) of the studied cases are also compared. The optimization variables are inclination angle (alpha), attack angle (beta), width / length ratio (b / a), height of the VG (h), interval between VG pair's front edges ( S1 ) for both one-row and three-row cases, also longitudinal spacing between each VG pair (SL) is added as an optimization variable for three-row case. It is found that three-row of CTWP type VGs can increase j/j(0) also increase f/f0, i.e., heat transfer enhance-ment is obtained with a pressure drop increment disadvantage and it is possible to achieve 24.05% heat transfer enhancement with the penalty of 17.27% pressure drop increment as compared to one-row of CTWP type VGs. Furthermore, the fact that the pressure drop has the maximum value does not mean that the heat transfer value is the maximum.
dc.identifier.doi10.1007/s00231-022-03332-w
dc.identifier.endpage1458
dc.identifier.issn0947-7411
dc.identifier.issn1432-1181
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85146936670
dc.identifier.scopusqualityQ2
dc.identifier.startpage1437
dc.identifier.urihttps://doi.org/10.1007/s00231-022-03332-w
dc.identifier.urihttps://hdl.handle.net/20.500.13099/2374
dc.identifier.volume59
dc.identifier.wosWOS:000923108200002
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorKuru, Muhammet Nasif
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofHeat and Mass Transfer
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250316
dc.subjectNumerical-Simulation
dc.subjectTube Bank
dc.subjectPlane
dc.subjectPerformances
dc.subjectChannel
dc.titleOptimization of heat and fluid flow over curved trapezoidal winglet pair type vortex generators with one-row and three-row
dc.typeArticle

Dosyalar